Eight. Protection against electric shock
Structural guarantee: When installed, in normal use, including open when changing a light bulb or starter, strong electric untouchable; hand can open the protective cover open (except for the bulb and lampholders substandard), electric shock protection should be sufficient.
Hand can move the parts to put the most unfavorable position, there should be adequate protection against electric shock.
3 a class of lamps:
(a) for the insulating case, can be touched should be reinforced insulation between the components and the strong electric or equivalent insulation
(b) a metal shell, can reach between components with strong electric double insulation or equivalent insulation, in which case double insulation can not be achieved, can be reinforced insulation (such as lamp holder)
c. basic insulation or equivalent insulation can only change a light bul b or starter before touch (certified replacement parts can be regarded as at least meet the basic insulation requirements)
(d) be open to changing a light bulb glass can not be regarded as additional insulation
- Class I lamps equipped with a cassette lamp holder shall:
 (a) normal use, the lamp can not be met, or (b) the use of a grounded metal lamp holder

Movable lamps by the plug and power cord connected to the power protection against electric shock not depend on the support surface; and its terminal can not touch.

5 cover and other components to provide protection against electric shock should have sufficient mechanical strength and reliably fixed, do not loose it in the normal operating conditions.

Charging of the capacitor will not cause excessive voltage (when disconnecting the power), otherwise there should discharge circuit.

IX. Waterproof and dustproof
 1.IP hierarchy and its testing (including pressure test) IP00? To IP68 (Table 0.1, 0.2)
Tide state: 91 ~ 95% 20-30? C, 48h
10 Insulation resistance and dielectric strength

 (1) Insulation resistance:
 Safe low voltage (SELV) (? 50V): 100V 1min?? 1M?
 Safe low voltage (? 50V): 500V 1min?? 2M?: Additional basic insulation of different polarity;? 4M?: Reinforced insulation, double insulation

 (2) Dielectric strength:
 SELV: 500V, 1min
 Non-SELV: 2U +1000 V (BI), 2U +1750 V (SI), 4U +2750 V-(RI), 1min

 Leakage current: ClassII: 0.5mA Class I: 1.0 mA

Xi. Climb creepage distances

 1.SELV components should also be a sufficient distance from the live parts of different polarity should be consistent with basic insulation requirements.
 (2) luminaires (IP20):

Table 4 AC (50/60Hz) the minimum distance of the sine wave voltage (general lighting)

(3) non-ordinary lamps (IPX1 above): Table 5
Table 5 AC (50/60Hz) the minimum distance of the sine wave voltage (non-ordinary lamps)

12 Endurance and thermal tests
(1) durable:
Lamps into the hot box (ta +10)? Cta = 25? Temperature voltage calibration on the C / or take lamps: 1.05 rated power voltage (tungsten); 1.1Vn (tubular fluorescent and other discharge lamps); Light string exception
Nothing more than normal operating conditions: 240h (10 days) to work properly:
Non-normal: In addition to the b-Africa normal circuit conditions, the 168h (7 days)
Seven cycles, each cycle is open 21h, stop 3h, b non-normal circuit conditions, the seventh cycle in the non-normal circuit conditions (AnnexC).
Non-normal operating conditions:
a.30N adjustment;
(b) tubular fluorescent and other discharge lamps abnormal circuit conditions;
c the same power of ordinary light bulbs instead of the special light bulb;
(d) the secondary short-circuit of the transformer-powered lamps
Durable lamps should be able to work, the lamp holder is not deformed, the nameplate is sti ll clearly visible.

(2) normal thermal test:

Conditions: a. Incubator temperature: 25?? 1? C (10 ~ 30? C and the best 25? C)
 exception to (b) Voltage: 1.05 rated power voltage (tungsten) or 1.06Vn (tubular fluorescent Gordon and other discharge lamps and lamps with the motor), string lights
c thermocouple monitoring to steady state (within 1 hour change? 1?)

 